Earth leakage tripping

Earth leakage keeps tripping? It could be an underground cable

If your earth leakage trips after rain, at night or whenever an outside circuit goes on, a damaged buried cable is one of the most likely causes. Here is how to narrow it down safely, and what we do next.

What the earth leakage is telling you

An earth leakage unit compares the current going out on a circuit with the current coming back. If some of it is leaking away, through damaged insulation, a wet fitting, a faulty appliance or a person, it trips in a fraction of a second. So when it trips, something is genuinely leaking. The question is where.

Common causes

  • Inside: a geyser element, a kettle, washing machine or other appliance, or a fault in the wiring.
  • Outside fittings: outdoor plugs, garden lights and security lights that let water in.
  • Pumps: pool pumps and borehole pumps, and the cables feeding them.
  • Underground cables: a cable to an outbuilding, gate, pump or lights with a damaged sheath, a bad joint or insulation that has broken down.

Signs the underground cable is to blame

  • It trips after rain or irrigation and settles down when the ground dries.
  • It trips as soon as the breaker for an outside circuit is switched on: the cottage, gate, pool, borehole or outside lights.
  • It started after digging, paving, fencing or planting near the cable route.
  • The equipment at the far end also struggles or loses power.

How to narrow it down safely

You can do this from the DB board without opening anything:

  1. Switch off all the circuit breakers that the earth leakage protects.
  2. Reset the earth leakage.
  3. Switch the breakers back on one at a time, waiting a moment after each.
  4. When it trips, the last breaker you switched on is the circuit with the problem. Leave that one off and switch the rest back on.

If the problem circuit feeds something inside, unplug the appliances on it and try again. If it feeds a cottage, gate, pool, borehole or outside lights, the underground cable is a prime suspect. That is where we come in.

Never bypass the earth leakage to get the power back. It is the device that stops a leaking cable from becoming a shock hazard. Do not open the DB board cover or dig near a live cable.

What we do

We test the suspect cable on its own. That shows whether the leak is in the buried cable or somewhere else in the installation. If it is the cable, we pinpoint the defective spot along it so only a small hole is dug, and the damaged section can be repaired instead of replacing the whole cable.

More detail on testing and pinpointing is on underground cable fault finding.

Earth leakage tripping: questions

Why does my earth leakage trip after rain?

Rain finds its way into anything that is damaged: a cut cable sheath, a joint that wasn't sealed, an outdoor plug or light fitting. Once water bridges live parts to earth, current leaks away and the earth leakage trips. If it only happens in wet weather and stops when the ground dries out, a buried cable or outdoor fitting is a strong suspect.

Why does my earth leakage trip at night?

Often because something switches on at night: garden lights, security lights or street lights on a day/night switch. If the circuit feeding them has a damaged cable, it trips when they come on. See street light and pole cable faults.

Can a damaged underground cable trip the earth leakage even when nothing is switched on at the far end?

Yes. If the cable itself is leaking to earth, it can trip the earth leakage whenever the cable is live, no matter what is plugged in at the other end.

Can I just bypass the earth leakage until it is fixed?

No. The earth leakage is the device that stops a leaking cable or fitting from becoming a shock hazard. Bypassing it removes that protection. Switch off the affected circuit instead and have it tested.

Is it safe to keep resetting it?

Repeated tripping is a warning, not a nuisance. If it trips again straight away, leave it off and get the circuit tested.

Earth leakage won't stay on?

Call to have the underground cable tested and the fault pinpointed.